7156 Owner’s Guide Diagnostics
October 1995 57
Print a Sample Receipt (Single or Continuous)
These tests print sample receipts, either once or continuously.
Caution: The DIP switches are set at the factory to predetermined settings and
should generally not be changed. If you must change the settings do so carefully
to avoid changing other functions.
1. Open the front cover and set the DIP switches to the settings in the table for
the test you want to run.
Switch 7 is always Off. Switch 8: On = knife, Off = non-knife
Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6 Option
On Off Off Off On Off Sample Receipt Via
Feed Button
On Off Off Off On On Continuous
Sample Receipt
2. Close the front cover and press the On Line button.
The printer automatically begins printing the sample receipt. If the Sample
Receipt Via Feed Button option is selected, the printer will stop printing after
all the character sets have been printed.
3. Press the Paper Feed button to repeat the test.
4. Press the On Line button to stop the test.
5. Set the DIP switches back to the settings for normal operation (on-line mode).
See “Switch Settings” in the “Communication” chapter for the settings.
6. Close the front cover and press the On Line button.
The green LED flashes when the printer cycles.