Diagnostics 7156 Owner’s Guide
October 199554
Exit the Data Scope Mode
1. Open the front cover and set the DIP switches to the following settings:
Switch 7 is always Off. Switch 8: On = knife, Off = non-knife
Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6
On Off Off On Off Off
2. Close the front cover and press the On Line button to take the printer off-line.
The green LED flashes when the printer cycles.
3. Set the DIP switches back to the settings for normal operation (on-line mode).
See “Switch Settings” in the “Communication” chapter for the settings.
4. Close the front cover and press the On Line button to put the printer on-line.
The green LED flashes when the printer cycles.
The printer will now communicate normally with the host system.